Support surfaces

VR-A4 active replacement mattress

Alternating-pressure replacement mattress with lateral rotation, controlled from the VR-7 footboard panel or its own pump.

Patients at risk
Very high risk
Cells
20, in two alternating sets
Patient weight
Up to 250 kg

Ask for a demonstration Documents

Overview

The VR-A4 is an alternating-pressure replacement mattress for patients at very high risk of pressure ulcers, and for patients who already have one. Twenty cells inflate and deflate in two sets on a ten-minute cycle, over a 50 mm foam safety base that supports the patient if power is lost.

On a VR-7 or VR-7 XW, the mattress is controlled from the bed’s footboard panel, and its alarms appear there. On other beds the pump hangs on the footboard and is used on its own.

  • Alternating and static modes

    A ten-minute alternating cycle, a static mode for comfort or procedures, and a firm mode for transfers and nursing care.

  • Lateral rotation

    Side cells turn the patient up to 20° each way on a programmed schedule, from the VR-7 panel only.

  • CPR valve

    The red CPR valve at the head end deflates the mattress in under 15 seconds.

  • Transport mode

    The mattress seals itself for up to 12 hours when the pump is disconnected.

Specifications

Mattress
Dimensions2,000 × 880 × 220 mm
Cells20 transverse cells, 200 mm, in two sets; head cells static
Foam base50 mm
CoverVapour-permeable, two-way stretch, welded seams
Maximum patient weight250 kg
Pump
Supply230 V AC, 50 Hz; 32 VA
Cycle10 minutes
NoiseUnder 28 dB(A) in night mode
AlarmsPower failure, low pressure, service due
Regulatory and service
ClassificationMedical device, Class I; CE and UKCA marked
ManufacturerVan Roon Medische Techniek B.V., Leiden, the Netherlands
Planned maintenancePump every 12 months; cover inspected at each cleaning

Dimensions are nominal and measured without a mattress unless stated. Safe working load is the total load the bed is designed to carry, including the patient, the mattress and any accessories fitted. Specifications may change without notice; the instructions for use supplied with each bed take precedence.

Options and accessories

Part numberDescriptionNotes
VRA4-0100PumpSpare or replacement
VRA4-0210Replacement top coverSupplied with fitting instructions
VRA4-0300Transport bagFor returns and storage

Options marked as retro-fit kits are fitted by a Van Roon engineer or by an engineer holding a current Level 2 certificate. For prices, contact sales@vanroon.uk. Spare parts are on the spare parts page.

Documents

DocumentTypeNumberRevisionDate
VR-A4 active replacement mattress: instructions for use
PDF, 86 KB, 14 pages
Instructions for use VRM-IFU-0A41-EN-GB E
VR-series support surfaces
PDF, 77 KB, 6 pages
Brochure VRM-BR-0090-UK 2023
Cleaning and decontamination of VR-series beds and surfaces
PDF, 29 KB, 2 pages
Guide VRM-DG-0005-UK F

Printed instructions for use are supplied with every bed. If you need a printed copy, or a copy in another format, contact info@vanroon.uk. Service documentation is available to trained engineers only.

Service

The VR-A4 pump needs planned maintenance every 12 months, including an electrical safety test and a check of each alarm. Covers should be inspected at every cleaning for tears, stains that will not clean and fluid under the cover. A mattress whose foam or cells are stained must be taken out of use.

Replacement covers, cells and pumps are on the spare parts page. For cleaning, see decontamination.

Customer notices for the VR-A4

Service desk 0808 157 0614

VR-A4 is manufactured by Van Roon Medische Techniek B.V., Leiden, the Netherlands, and supplied in the United Kingdom and Ireland by Van Roon Medical UK Ltd. Available in the UK and Ireland since 2022. Always read the instructions for use before using the product.